Dry run & stop protection. Guardian systems

Dry run & stop protection. Guardian systems

SPEAK TO US TODAY +31 85 00 743 00

Dry run protection shuts down the pump if the discharge pressure rises above a set level. This protection allows the pump to be switched off when its operation is ineffective or when a specific task (e.g., emptying a tank) has been completed.

Dry run protection extends the life of the diaphragms and reduces compressed air consumption. The pump shut-off pressure level is set using the knob located on the protection device.

The solution is fully pneumatic and can be powered by the same air as the diaphragm pump, which facilitates installation and operation of the device. After activation, the pump must be started manually.

Dry run protection shuts down the pump if the discharge pressure rises above a set level. This protection allows the pump to be switched off when its operation is ineffective or when a specific task (e.g., emptying a tank) has been completed.

Dry run protection extends the life of the diaphragms and reduces compressed air consumption. The pump shut-off pressure level is set using the knob located on the protection device.

The solution is fully pneumatic and can be powered by the same air as the diaphragm pump, which facilitates installation and operation of the device. After activation, the pump must be started manually.

How does the Guardian work?

The Guardian is a fully pneumatic dry-run and stop protection for air operated diaphragm pumps. It is connected to the same compressed air supply as the pump and needs no electrical connection.

The Guardian monitors the pressure on the discharge side of the pump. As soon as the pump no longer works effectively – for example because a tank or drum is empty – or the pressure rises above the set level, it shuts off the compressed air supply to the pump. The switching point is easily set with a knob. After shutdown, the pump is restarted manually.

This prevents the pump from running unnecessarily, extends diaphragm life and saves compressed air.

  • How does the Guardian work?

The Guardian is a fully pneumatic dry-run and stop protection for air operated diaphragm pumps. It is connected to the same compressed air supply as the pump and needs no electrical connection.

The Guardian monitors the pressure on the discharge side of the pump. As soon as the pump no longer works effectively – for example because a tank or drum is empty – or the pressure rises above the set level, it shuts off the compressed air supply to the pump. The switching point is easily set with a knob. After shutdown, the pump is restarted manually.

This prevents the pump from running unnecessarily, extends diaphragm life and saves compressed air.